Air-heater sections
Air-heaters are used to keep normal temperature in locomotive driver cab and rooms for special machines by means of circulating water from diesel engine cooling system. Air-heater section is a replaceable item of a heater. Miscellaneous models of heaters are used depending on locomotive or special machines design features
Air-heater sections 2ТЭ116.10.70.025 СБ are used to heat the driver’s cabin with water circulating in the cooling system of locomotive 2ТЭ116 diesel engines
Technical characteristics
No
|
Parameter name
|
Section
|
2ТЭ116.10.70.025 СБ
|
1
|
Locomotive series
|
2ТЭ116
|
2
|
Cooling tube working length, mm
|
291
|
3
|
Overall dimensions, mm
|
480х211х243
|
4
|
Plate pitch, mm
|
2,3
|
5
|
Total weight, kg
|
13,8
|
6
|
Air cooling surface, m2
|
7,9
|
7
|
Warranty period
|
12 months from the shipment date
|
Air-heater core ТЭ2.47.15 СБ is used in air-heaters sections of drws. ТЭ2.47.6 СБ and ТЭ10.10.70.012 СБ that are used to heat driver’s cabin of locomotives ТЭ3, 2ТЭ10Л
Technical characteristics
No
|
Parameter name
|
Section
|
ТЭ2.47.15 СБ
|
1
|
Locomotive series
|
ТЭ3, 2ТЭ10Л
|
2
|
Cooling tube working length, mm
|
314
|
3
|
Overall dimensions, mm
|
360х212х325
|
4
|
Plate pitch, mm
|
4
|
5
|
Total weight, kg
|
14,2
|
6
|
Air cooling surface, m2
|
8,318
|
7
|
Warranty period
|
12 months from the shipment date
|
Air-heater sections ТЭ2.47.6 СБ1 and ТЭ10.70.012 СБ are used to heat driver’s cabin with water circulating in the diesel engine cooling system
Technical characteristics
No
|
Parameter name
|
Section
|
ТЭ2.47.6 СБ
|
ТЭ10.10.70.012 СБ
|
|
Locomotive series
|
ТЭ3, 2ТЭ10Л
|
2
|
Air-swept surface, m2
|
8,318
|
3
|
Inner water-swept surface, m2
|
2,039
|
4
|
Number of working tubes in a section
|
184
|
5
|
Tube type according to GOST 2936-75
|
radiator flat-oval seamless
|
6
|
Tubes arrangement in array
|
staggered, at an angle 60° to front edge
|
7
|
Depth number of tubes rows
|
8
|
8
|
Number of water flows in section
|
1
|
9
|
Tubes inner axial dimensions, mm
|
3,0х16,5
|
10
|
Tubes section length between arrays, mm
|
314
|
11
|
Cross-sectional area of tubes of one section, m2
|
0,00863
|
12
|
Cooling plates thickness, mm
|
0,18
|
13
|
Tube wall thickness, mm
|
0,25
|
14
|
Front cross-sectional area for airflow, m2
|
0,09734
|
15
|
Airflow cross-sectional area, m2
|
0,06888
|
16
|
Plate pitch on the tubes, mm
|
4
|
17
|
Number of cooling plates (according to the drawing) in one section
|
77х2
|
18
|
Total weight, kg
|
31
|
19
|
Overall dimensions, mm
|
420х212х486
|
420х212х502
|
20
|
Installation dimension, mm
|
406
|
320
|
21
|
Warranty period
|
12 months from the shipment date
|
Air-heaters sections ТЭМ18.10.72.030 СБ are used to heat driver’s cabin with water circulating in the diesel engine cooling system of locomotive
Technical characteristics
No
|
Parameter name
|
Section
|
ТЭМ18.10.72.030 СБ
|
1
|
Locomotive series
|
ТЭМ18.Д10
|
2
|
Cooling tube working length, mm
|
297
|
3
|
Overall dimensions, mm
|
436х210х586
|
4
|
Installation dimension, mm
|
406
|
5
|
Plate pitch, mm
|
2,3
|
6
|
Total weight, kg
|
23,5
|
7
|
Air cooling surface, m2
|
7,45
|
8
|
Warranty period
|
12 months from the shipment date
|
Air-heater section 027.10.73.50 СБ is used to heat driver’s cabin by means of cooling liquid (water) of cooling system of locomotive diesel engine flowing (circulating) through it
Technical characteristics
No
|
Parameter name
|
Section
|
027.10.73.50СБ
|
1
|
Air-swept surface, m2
|
6,2
|
2
|
Inner liquid-swept surface, m2
|
0,9
|
3
|
Number of working tubes in section
|
68
|
4
|
Tubes types according to GOST 2936-75
|
radiator flat-oval seamless
|
5
|
Tubes arrangement in array
|
staggered
|
6
|
Depth number of tubes rows
|
4
|
7
|
Number of liquid flows in section
|
1
|
8
|
Tubes inner axial dimensions, mm
|
2,9х16,2
|
9
|
Tubes section length between arrays, mm
|
300
|
10
|
Cross-sectional area of tubes of one section, m2
|
0,00307
|
11
|
Cooling plates thickness, mm
|
0,1
|
12
|
Tube wall thickness, mm
|
0,55
|
13
|
Airflow cross-sectional area, m2
|
0,051
|
14
|
Number of cooling plates (according to drawing) in one section
|
208
|
15
|
Total weight, kg
|
13
|
16
|
Warranty period
|
12 months from the shipment date
|
Air-heater core 2ТЭ10.10.70.020 СБ is used to heat driver’s cabin of locomotives
Technical characteristics
No
|
Parameter name
|
Section
|
2ТЭ10.10.70.020 СБ
|
1
|
Locomotive series
|
2ТЭ10Л, М62
|
2
|
Air-swept surface, not less, m2
|
4,98
|
3
|
Inner liquid-swept surface m2
|
0,152
|
4
|
Working tubes number per section
|
68
|
5
|
Tubes types according to GOST 2936-75
|
radiator flat-oval seamless
|
6
|
Tubes arrangement in array
|
staggered
|
7
|
Depth number of tubes rows
|
8
|
8
|
Number of liquid flows per section
|
1
|
9
|
Tubes inner axial dimensions, , mm
|
2,9х16,2
|
10
|
Tubes section length between arrays, mm
|
291
|
11
|
Cross-sectional area of tubes of one section, m2
|
0,00307
|
12
|
Cooling plates thickness, mm
|
0,1
|
13
|
Tube wall thickness, mm
|
0,55
|
14
|
Front cross-sectional area for airflow,m2
|
0,0448
|
15
|
Airflow cross-sectional area,m2
|
0,0271
|
16
|
Ribbed plates pitch, mm
|
2,83
|
17
|
Number of cooling plates (according to drawing) per section
|
100х2
|
18
|
Overall dimensions, mm
|
290х193х495
|
19
|
Total weight, kg
|
18,3
|
20
|
Warranty period
|
12 months from the shipment date
|
|
|